Schematic Viewer 한국어 日本語 Open the tool

Supported files and troubleshooting

Which schematic PDFs analyze well, and what to check and how to re-export when a file won't open or the connections look wrong.

Last updated: 2026-11-12

PDFs that work well

Schematic Viewer reads the lines (vector paths) and text (text layer) in a PDF to infer connections, so PDFs exported directly from a schematic program work best.

Schematic programWhat the tool usesSamples checkedConditions and limits
KiCadLines and text; wire colour in colour exports10 scored public samples: 7 KiCad 5 exports, 3 KiCad 7 exportsScores are for colour exports and drop for black-and-white copies of the same samples. No KiCad 6 or 8 exports have been checked.
Eagle / Fusion ElectronicsLines and text1 scored public sample (an Adafruit board); 1 unscored local sample (lettering drawn as lines)PDFs that draw their lettering as lines limit net names and name search. No Fusion Electronics exports have been checked.
Altium DesignerThe netlist and pin marks in Smart PDF bookmarks (when present)1 unscored local sample (Smart PDF)No score against true connections. No plain PDF exports without the bookmark netlist have been checked.
OrCAD CaptureLink data in the PDF (net labels, part boxes) to tell labels and parts apartNo sample checked against true connectionsThe feature exists but its accuracy is unverified. Exports are often black and white, where different nets can merge.
Others (EasyEDA, redrawn documentation schematics …)Lines and text1 unscored local sample (a redrawn documentation schematic)Likely to work when wires are straight lines and text is real text. No EasyEDA exports have been checked.

Samples as of 2026-11-03. Scores for the public samples and how they are tested are on the about page. "Not checked" does not mean it fails — only that its accuracy has not been verified.

In short, analysis works best when the PDF:

One sheet, three kinds of PDF

To show the difference, we saved one small schematic made for this page (an illustration, not a real product) in three ways and opened each in this site's tool. Results as checked on 2026-11-03:

How the PDF was savedWhat the tool showedMeaning
Lines and text kept, as a schematic program exports it (vector)Nets 4, Parts 4. VCC, GND, SENSE_EN and LED_OUT are listed; picking SENSE_EN highlights its wiresCan be analyzed
The same sheet turned into a picture (150 dpi) inside a PDFThe drawing shows, but Nets 0 and Parts 0, with the message "This PDF has no line or text data, so its connections can't be analyzed"Same as a scanned or captured PDF; export again from the original
A copy of the vector PDF with an open password"Password-protected PDFs can't be opened"; the drawing does not openA copy without the password is needed
The vector PDF opened: GND, VCC, LED_OUT and SENSE_EN are listed and the SENSE_EN wires are highlighted in cyan.
Vector PDF: names appear in the list and the wires of the selected net (SENSE_EN) are highlighted.
The picture-only PDF opened: the drawing is visible but Nets 0 and Parts 0, and a message says the PDF has no line or text data so its connections cannot be analyzed.
Picture-only PDF: the drawing is still shown, but there are no nets or parts and a message says it cannot be analyzed.
Trying to open the password-protected PDF: a message says password-protected PDFs can't be opened.
PDF with an open password: the file is not opened and only the message is shown.

Download the test files and try it yourself

Anyone can re-check the results above with these three files. They were made by this site for testing and are not real product drawings.

FileSize · SHA-256How it was madeExpected result
formats-vector.pdf2,170 bytes
a9dbccfad1020ff6a284062740f6349318d948c36b8fdc8cd5b87a491cf6444f
lines and text drawn directly with Python ReportLab (2026-11-03)Nets 4 (GND, VCC, LED_OUT, SENSE_EN), Parts 4; picking SENSE_EN highlights its wires
formats-image.pdf32,413 bytes
14f14e850c6dc42e394879077149d6fbfd33536c58814da5eed230bdae07ec09
the vector PDF rendered to a 150 dpi PNG (1241×875) and wrapped in a PDF with img2pdf 0.6.3the drawing shows, but Nets 0 and Parts 0, with "This PDF has no line or text data, so its connections can't be analyzed"
formats-password.pdf3,054 bytes
dc531b2ffcda8ed94470ffc5242c1db507e90a6a771826e7900be27f996f841e
a copy of the vector PDF with the open password schematic (AES-256), set with qpdf 11.9.0 (re-made 2026-11-12)"Password-protected PDFs can't be opened"; the drawing does not open. Opened with the password schematic in a PDF reader, it is the same drawing as the vector PDF

The password file exists to test what happens with a password-protected PDF; its password is a published test value. Encryption adds random values, so re-making it the same way gives a different hash but the same result.

How to tell whether a result can be trusted

  1. Is the lettering text? If you can drag-select a part reference in a PDF reader, it is text. If not, name search and net names are limited.
  2. Check one net you know: pick GND or a supply whose location you know and see whether the highlighted area matches what the original shows.
  3. Compare label counts: the number of places a name search finds should match the net's label count (the ×11 next to it). If they differ, some labels may have been judged not to touch a wire; find those places with the search and check them yourself.
  4. Connections through parts: the tool does not merge connections through a resistor, switch, ferrite bead or other part into one net. Check such relations by selecting the part and reading the drawing.

For a worked example with screenshots of each step, see the step-by-step example.

What each message means

"Only PDF files can be opened"

The file is not a PDF (an image, an archive, a CAD source file …). Export a PDF from your schematic program and open that, and check that the file name ends in .pdf.

"Password-protected PDFs can't be opened"

A browser cannot read a PDF protected with an open password. If you know the password, open it in a PDF reader and save a copy without the password (or use "Print → Save as PDF"), then open the copy. For company documents, check your security policy first.

"Unable to read this PDF"

Usually the file is damaged or was opened before its download finished. Download the original again; if that fails, export the PDF again from your schematic program. Very old browsers can also cause this — a current Chrome, Edge, Safari or Firefox is recommended.

"This PDF has no line or text data"

The PDF is most likely a scan or a screenshot saved as PDF. You can still view the drawing, but its lines and letters are pictures, so the connections can't be analyzed and names can't be searched. Export the PDF again from the original schematic program.

It opens, but the result looks wrong

The net list is empty or has few names

The PDF has no text data (text layer): its lettering was often drawn as lines or stored as a picture. Names can't be read, so the net list and name search stay empty. If the PDF has line data, clicking a wire still highlights its connections. For OrCAD PDFs, the part data inside the PDF still provides the parts list and part search. Look for an export option that keeps fonts as text (for example "use TrueType fonts" or "don't convert text to outlines") and export again.

Different nets appear merged

In black-and-white PDFs wires and symbols share one colour, so a part outline or a pin line can be mistaken for a wire. Exporting in colour fixes most cases. If it keeps happening with a drawing, tell us through the contact page — a public example showing the same problem helps us fix it faster than a private drawing.

Some labels with the same name are not connected

A label slightly away from its wire, or overlapping a pin name, may not be recognized as a label. Search still finds every occurrence, so search for the name to check.

A part has no value

Values written far from the reference or in a different direction may not be grouped with it. Click the part and check the drawing. See Finding parts in a schematic PDF.

The drawing stays grey or looks rough

"Rendering drawing" is shown while the PDF is being drawn. If it never appears, the browser cannot draw the PDF and an outline drawing from the analysis is shown instead. Please update your browser.

Multi-page schematics

Each page is analyzed on its own, and nets with the same name are combined in the list by name only. If the original used a local label confined to one sheet, they may in fact be separate nets (see label scope in Reading schematics). Pages containing the selected net are marked with a dot on the page numbers, and the label buttons move across pages. Connections that cross pages without a name (hierarchical sheet ports, for example) are not followed yet.